Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38428580

RESUMO

Atrial fibrillation (AF) causes progressive structural and electrical changes in the atria that can be summarized within the general concept of atrial remodeling. In parallel, other clinical characteristics and comorbidities may also affect atrial tissue properties and make the atria susceptible to AF initiation and its long-term persistence. Overall, pathological atrial changes lead to atrial cardiomyopathy with important implications for rhythm control. Although there is general agreement on the role of the atrial substrate for successful rhythm control in AF, the current classification oversimplifies clinical management. The classification uses temporal criteria and does not establish a well-defined strategy to characterize the individual-specific degree of atrial cardiomyopathy. Better characterization of atrial cardiomyopathy may improve the decision-making process on the most appropriate therapeutic option. We review current scientific evidence and propose a practical characterization of the atrial substrate based on 3 evaluation steps starting with a clinical evaluation (step 1), then assess outpatient complementary data (step 2), and finally include information from advanced diagnostic tools (step 3). The information from each of the steps or a combination thereof can be used to classify AF patients in 4 stages of atrial cardiomyopathy, which we also use to estimate the success on effective rhythm control.

4.
Nat Commun ; 14(1): 4613, 2023 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-37542075

RESUMO

Electromechanical characterization during atrial fibrillation (AF) remains a significant gap in the understanding of AF-related atrial myopathy. This study reports mechanistic insights into the electromechanical remodeling process associated with AF progression and further demonstrates its prognostic value in the clinic. In pigs, sequential electromechanical assessment during AF progression shows a progressive decrease in mechanical activity and early dissociation from its electrical counterpart. Atrial tissue samples from animals with AF reveal an abnormal increase in cardiomyocytes death and alterations in calcium handling proteins. High-throughput quantitative proteomics and immunoblotting analyses at different stages of AF progression identify downregulation of contractile proteins and progressive increase in atrial fibrosis. Moreover, advanced optical mapping techniques, applied to whole heart preparations during AF, demonstrate that AF-related remodeling decreases the frequency threshold for dissociation between transmembrane voltage signals and intracellular calcium transients compared to healthy controls. Single cell simulations of human atrial cardiomyocytes also confirm the experimental results. In patients, non-invasive assessment of the atrial electromechanical relationship further demonstrate that atrial electromechanical dissociation is an early prognostic indicator for acute and long-term rhythm control.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Doenças Musculares , Humanos , Animais , Suínos , Prognóstico , Cálcio/metabolismo , Átrios do Coração/metabolismo
7.
J Interv Card Electrophysiol ; 66(8): 1889-1899, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36807734

RESUMO

BACKGROUND: Electrical isolation of pulmonary veins (PV) with high-power short-duration (HPSD) radiofrequency application (RFa) may reduce the duration of atrial fibrillation (AF) ablation, without compromising the procedural efficacy and safety in comparison with the conventional approach. This hypothesis has been generated in several observational studies; the POWER FAST III will test it in a randomized multicenter clinical trial. METHODS: It is a multicenter randomized, open-label and non-inferiority clinical trial with two parallel groups. AF ablation using 70 W and 9-10 s RFa is compared with the conventional technique using 25-40 W RFa guided by numerical lesion indexes. The main efficacy objective is the incidence of atrial arrhythmia recurrences electrocardiographically documented during 1-year follow-up. The main safety objective is the incidence of endoscopically detected esophageal thermal lesions (EDEL). This trial includes a substudy of incidence of asymptomatic cerebral lesions detected by magnetic resonance imaging (MRI) after ablation. RESULTS: A randomized clinical trial compares for the first time high-power short-duration and conventional ablation in order to obtain data about the efficacy and safety of the high-power technique in an adequate methodological context. CONCLUSIONS: The results of the POWER FAST III could support the use of the high-power short-duration ablation in clinical practice. REGISTRATION: ClinicalTrials.gov: NTC04153747.

8.
Rev Esp Cardiol (Engl Ed) ; 75(9): 709-716, 2022 Sep.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-34896031

RESUMO

INTRODUCTION AND OBJECTIVES: HeartLogic is a multiparametric algorithm incorporated into implantable cardioverter-defibrillators (ICD). The associated alerts predict impending heart failure (HF) decompensations. Our objective was to analyze the association between alerts and clinical events and to describe the implementation of a protocol for remote management in a multicenter registry. METHODS: We evaluated study phase 1 (the investigators were blinded to the alert state) and phases 2 and 3 (after HeartLogic activation, managed as per local practice and with a standardized protocol, respectively). RESULTS: We included 288 patients from 15 centers. In phase 1, the median observation period was 10 months and there were 73 alerts (0.72 alerts/patient-y), with 8 hospitalizations and 2 emergency room admissions for HF (0.10 events/patient-y). There were no HF hospitalizations outside the alert period. In the active phases, the median follow-up was 16 (95%CI, 15-22) months and there were 277 alerts (0.89 alerts/patient-y); 33 were associated with HF hospitalizations or HF death (n=6), 46 with minor decompensations, and 78 with other events. The unexplained alert rate was 0.39 alerts/patient-y. Outside the alert state, there was only 1 HF hospitalization and 1 minor HF decompensation. Most alerts (82% in phase 2 and 81% in phase 3; P=.861) were remotely managed. The median NT-proBNP value was higher within than outside the alert state (7378 vs 1210 pg/mL; P <.001). CONCLUSIONS: The HeartLogic index was frequently associated with HF-related events and other clinically relevant situations, with a low rate of unexplained events. A standardized protocol allowed alerts to be safely and remotely detected and appropriate action to be taken on them.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Algoritmos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Sistema de Registros
9.
Sci Rep ; 11(1): 18722, 2021 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-34580343

RESUMO

Delayed gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) imaging requires novel and time-efficient approaches to characterize the myocardial substrate associated with ventricular arrhythmia in patients with ischemic cardiomyopathy. Using a translational approach in pigs and patients with established myocardial infarction, we tested and validated a novel 3D methodology to assess ventricular scar using custom transmural criteria and a semiautomatic approach to obtain transmural scar maps in ventricular models reconstructed from both 3D-acquired and 3D-upsampled-2D-acquired LGE-CMR images. The results showed that 3D-upsampled models from 2D LGE-CMR images provided a time-efficient alternative to 3D-acquired sequences to assess the myocardial substrate associated with ischemic cardiomyopathy. Scar assessment from 2D-LGE-CMR sequences using 3D-upsampled models was superior to conventional 2D assessment to identify scar sizes associated with the cycle length of spontaneous ventricular tachycardia episodes and long-term ventricular tachycardia recurrences after catheter ablation. This novel methodology may represent an efficient approach in clinical practice after manual or automatic segmentation of myocardial borders in a small number of conventional 2D LGE-CMR slices and automatic scar detection.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Cicatriz/patologia , Taquicardia Ventricular/diagnóstico por imagem , Idoso , Animais , Arritmias Cardíacas/patologia , Cardiomiopatias/metabolismo , Cicatriz/diagnóstico por imagem , Biologia Computacional/métodos , Meios de Contraste , Feminino , Gadolínio/farmacologia , Ventrículos do Coração/fisiopatologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Isquemia Miocárdica/patologia , Miocárdio/patologia , Recidiva , Suínos , Taquicardia Ventricular/fisiopatologia
10.
Eur Cardiol ; 16: e21, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34093742

RESUMO

Catheter ablation remains the most effective and relatively minimally invasive therapy for rhythm control in patients with AF. Ablation has consistently shown a reduction of arrhythmia-related symptoms and significant improvement in patients' quality of life compared with medical treatment. The ablation strategy relies on a well-established anatomical approach of effective pulmonary vein isolation. Additional anatomical targets have been reported with the aim of increasing procedure success in complex substrates. However, larger ablated areas with uncertainty of targeting relevant regions for AF initiation or maintenance are not exempt from the potential risk of complications and pro-arrhythmia. Recent developments in mapping tools and computational methods for advanced signal processing during AF have reported novel strategies to identify atrial regions associated with AF maintenance. These novel tools - although mainly limited to research series - represent a significant step forward towards the understanding of complex patterns of propagation during AF and the potential achievement of patient-tailored AF ablation strategies for the near future.

12.
Infect Dis Ther ; 10(2): 801-814, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33715099

RESUMO

INTRODUCTION: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection causes a severe respiratory disease with a 3% global mortality. In the absence of effective treatment, controlling of risk factors that predispose to severe disease is essential to reduce coronavirus disease 2019 (COVID-19) mortality. Large observational studies suggest that exercise can reduce the risk of all-cause and disease-specific mortality. The aim of this study was to analyze the influence of the baseline physical activity level on COVID-19 mortality METHODS: This is a retrospective cohort study that included patients between 18 and 70 years old, diagnosed with COVID-19 and hospitalized in our center between February 15 and April 15, 2020. After discharge all the patients included in the study were contacted by telephone. Baseline physical activity level was estimated using the Rapid Assessment of Physical Activity Scale questionnaire and patients were divided into two groups for comparison: sedentary patients (group 1) and active patients (group 2). RESULTS: During the study period 552 patients were admitted to our hospital and met the inclusion criteria. Global mortality in group 1 was significantly higher than in group 2 (13.8% vs 1.8%; p < 0.001). Patients with a sedentary lifestyle had increased COVID-19 mortality independently of other risk factors previously described (hazard ratio 5.91 (1.80-19.41); p = 0.003). CONCLUSION: A baseline sedentary lifestyle increases the mortality of hospitalized patients with COVID-19. This finding may be of great utility in the prevention of severe COVID-19 disease.

14.
Pacing Clin Electrophysiol ; 44(2): 341-359, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33283883

RESUMO

Anatomical-based approaches, targeting either pulmonary vein isolation (PVI) or additional extra PV regions, represent the most commonly used ablation treatments in symptomatic patients with atrial fibrillation (AF) recurrences despite antiarrhythmic drug therapy. PVI remains the main anatomical target during catheter-based AF ablation, with the aid of new technological advances as contact force monitoring to increase safety and effective radiofrequency (RF) lesions. Nowadays, cryoballoon ablation has also achieved the same level of scientific evidence in patients with paroxysmal AF undergoing PVI. In parallel, electrical isolation of extra PV targets has progressively increased, which is associated with a steady increase in complex cases undergoing ablation. Several atrial regions as the left atrial posterior wall, the vein of Marshall, the left atrial appendage, or the coronary sinus have been described in different series as locations potentially involved in AF initiation and maintenance. Targeting these regions may be challenging using conventional point-by-point RF delivery, which has opened new opportunities for coadjuvant alternatives as balloon ablation or selective ethanol injection. Although more extensive ablation may increase intraprocedural AF termination and freedom from arrhythmias during the follow-up, some of the targets to achieve such outcomes are not exempt of potential severe complications. Here, we review and discuss current anatomical approaches and the main ablation technologies to target atrial regions associated with AF initiation and maintenance.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos , Resultado do Tratamento
16.
Heart Rhythm ; 17(8): 1232-1240, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32325197

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a growing health burden, and pulmonary vein isolation (PVI) using cryoballoon (CB) or radiofrequency (RF) represents an attractive therapeutic option. Sex-specific differences in the epidemiology, pathophysiology, and clinical presentation of AF and PVI are recognized. OBJECTIVE: We aimed at comparing the efficacy, safety, and procedural characteristics of CB and RF in women and men undergoing a first PVI procedure. METHODS: We searched for randomized controlled trials and prospective observational studies comparing CB and RF ablation with at least 1 year of follow-up. After merging individual patient data from 18 data sets, we investigated the sex-specific (procedure failure defined as recurrence of atrial arrhythmia, reablation, and reinitiation of antiarrhythmic medication), safety (periprocedural complications), and procedural characteristics of CB vs RF using Kaplan-Meier and multilevel models. RESULTS: From the 18 studies, 4840 men and 1979 women were analyzed. An analysis stratified by sex correcting for several covariates showed a better efficacy of CB in men (hazard ratio for recurrence 0.88; 95% confidence interval 0.78-0.98, P = .02) but not in women (hazard ratio 0.98; 95% confidence interval 0.83-1.16; P = .82). For women and men, the energy source had no influence on the occurrence of at least 1 complication. For both sexes, the procedure time was significantly shorter with CB (-22.5 minutes for women and -27.1 minutes for men). CONCLUSION: CB is associated with less long-term failures in men. A better understanding of AF-causal sex-specific mechanisms and refinements in CB technologies could lead to higher success rates in women.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Veias Pulmonares/cirurgia , Fibrilação Atrial/fisiopatologia , Humanos , Recidiva , Fatores Sexuais , Resultado do Tratamento
17.
Europace ; 22(5): 704-715, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31840163

RESUMO

AIMS: Atrial electrical remodelling (AER) is a transitional period associated with the progression and long-term maintenance of atrial fibrillation (AF). We aimed to study the progression of AER in individual patients with implantable devices and AF episodes. METHODS AND RESULTS: Observational multicentre study (51 centres) including 4618 patients with implantable cardioverter-defibrillator +/-resynchronization therapy (ICD/CRT-D) and 352 patients (2 centres) with pacemakers (median follow-up: 3.4 years). Atrial activation rate (AAR) was quantified as the frequency of the dominant peak in the signal spectrum of AF episodes with atrial bipolar electrograms. Patients with complete progression of AER, from paroxysmal AF episodes to electrically remodelled persistent AF, were used to depict patient-specific AER slopes. A total of 34 712 AF tracings from 830 patients (87 with pacemakers) were suitable for the study. Complete progression of AER was documented in 216 patients (16 with pacemakers). Patients with persistent AF after completion of AER showed ∼30% faster AAR than patients with paroxysmal AF. The slope of AAR changes during AF progression revealed patient-specific patterns that correlated with the time-to-completion of AER (R2 = 0.85). Pacemaker patients were older than patients with ICD/CRT-Ds (78.3 vs. 67.2 year olds, respectively, P < 0.001) and had a shorter median time-to-completion of AER (24.9 vs. 93.5 days, respectively, P = 0.016). Remote transmissions in patients with ICD/CRT-D devices enabled the estimation of the time-to-completion of AER using the predicted slope of AAR changes from initiation to completion of electrical remodelling (R2 = 0.45). CONCLUSION: The AF progression shows patient-specific patterns of AER, which can be estimated using available remote-monitoring technology.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Desfibriladores Implantáveis , Marca-Passo Artificial , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Pré-Escolar , Humanos
19.
Circ Res ; 125(6): 609-627, 2019 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-31366278

RESUMO

RATIONALE: Costly proprietary panoramic multielectrode (64-256) acquisition systems are being increasingly used together with conventional electroanatomical mapping systems for persistent atrial fibrillation (PersAF) ablation. However, such approaches target alleged drivers (rotational/focal) regardless of their activation frequency dynamics. OBJECTIVES: To test the hypothesis that stable regions of higher than surrounding instantaneous frequency modulation (iFM) drive PersAF and determine whether rotational activity is specific for such regions. METHODS AND RESULTS: First, novel single-signal algorithms based on instantaneous amplitude modulation (iAM) and iFM to detect rotational-footprints without panoramic multielectrode acquisition systems were tested in 125 optical movies from 5 ex vivo Langendorff-perfused PersAF sheep hearts (sensitivity/specificity, 92.6/97.5%; accuracy, 2.5-mm) and in computer simulations. Then, 16 pigs underwent high-rate atrial pacing to develop PersAF. After a median (interquartile range [IQR]) of 4.4 (IQR, 2.5-9.9) months of high-rate atrial pacing followed by 4.1 (IQR, 2.7-5.4) months of self-sustained PersAF, pigs underwent in vivo high-density electroanatomical atrial mapping (4920 [IQR, 4435-5855] 8-second unipolar signals per map). The first 4 out of 16 pigs were used to adapt ex vivo optical proccessing of iFM/iAM to in vivo electrical signals. In the remaining 12 out of 16 pigs, regions of higher than surrounding average iFM were considered leading-drivers. Two leading-driver + rotational-footprint maps were generated 2.6 (IQR, 2.4-2.9) hours apart to test leading-driver spatiotemporal stability and guide ablation. Leading-driver regions (2.5 [IQR, 2.0-4.0] regions/map) exactly colocalized (95.7%) in the 2 maps, and their ablation terminated PersAF in 92.3% of procedures (radiofrequency until termination, 16.9 [IQR, 9.2-35.8] minutes; until nonsustainability, 20.4 [IQR, 12.8-44.0] minutes). Rotational-footprints were found at every leading-driver region, albeit most (76.8% [IQR, 70.5%-83.6%]) were located outside. Finally, the translational ability of this approach was tested in 3 PersAF redo patients. CONCLUSIONS: Both rotational-footprints and spatiotemporally stable leading-driver regions can be located using iFM/iAM algorithms without panoramic multielectrode acquisition systems. In pigs, ablation of leading-driver regions usually terminates PersAF and prevents its sustainability. Rotational activations are sensitive but not specific to such regions. Single-signal iFM/iAM algorithms could be integrated into conventional electroanatomical mapping systems to improve driver detection accuracy and reduce the cost of patient-tailored/mechanistic approaches.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Frequência Cardíaca/fisiologia , Imageamento Tridimensional/métodos , Potenciais de Ação/fisiologia , Adulto , Idoso , Animais , Fibrilação Atrial/diagnóstico por imagem , Feminino , Humanos , Preparação de Coração Isolado/métodos , Masculino , Pessoa de Meia-Idade , Ovinos , Suínos
20.
Circ Arrhythm Electrophysiol ; 12(3): e007080, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30879334

RESUMO

BACKGROUND: Ablation of some myocardial substrates requires catheter-based radiofrequency delivery at the root of a great artery. We studied the safety and efficacy parameters associated with catheter-based radiofrequency delivery at the root of the aorta and pulmonary artery. METHODS: Thirty-six pigs underwent in-vivo catheter-based ablation under continuous contact-force and lesion index (power, contact-force, and time) monitoring during 60-s radiofrequency delivery with an open-irrigated tip catheter. Twenty-eight animals were allocated to groups receiving 40 W (n=9), 50 W (n=10), or 60 W (n=9) radiofrequency energy, and acute (n=22) and chronic (n=6) arterial wall damage was quantified by multiphoton microscopy in ex vivo samples. Adjacent myocardial lesions were quantified in parallel samples. The remaining 8 pigs were used to validate safety and efficacy parameters. RESULTS: Acute collagen and elastin alterations were significantly associated with radiofrequency power, although chronic assessment revealed vascular wall recovery in lesions without steam pop. The main parameters associated with steam pops were median peak temperature >42°C and impedance falls >23 ohms. Unlike other parameters, lesion index values of 9.1 units (interquartile range, 8.7-9.8) were associated with the presence of adjacent myocardial lesions in both univariate ( P=0.03) and multivariate analyses ( P=0.049; odds ratio, 1.99; 95% CI, 1.02-3.98). In the validation group, lesion index values using 40 W over a range of contact-forces correlated with the size of radiofrequency lesions (R2=0.57; P=0.03), with no angiographic or histopathologic signs of coronary artery damage. CONCLUSIONS: Lesion index values obtained during 40 W radiofrequency applications reliably monitor safe and effective lesion creation at the root of the great arteries.


Assuntos
Aorta/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Artéria Pulmonar/cirurgia , Irrigação Terapêutica/instrumentação , Animais , Aorta/metabolismo , Aorta/patologia , Ablação por Cateter/efeitos adversos , Colágeno/metabolismo , Elastina/metabolismo , Desenho de Equipamento , Masculino , Modelos Animais , Duração da Cirurgia , Pressão , Artéria Pulmonar/metabolismo , Artéria Pulmonar/patologia , Medição de Risco , Fatores de Risco , Sus scrofa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...